Nanosensors DT-NCLR

As low as $1,185.00
In stock
SKU
DT-NCLR -(select options)

Diamond Coated Tapping Mode AFM Probe with Long Cantilever

Ordering Information

Quantity

Coating

Part Number

Price
10 
probes
Diamond DT-NCLR-10 $1,185.00
20 
probes
Diamond DT-NCLR-20 $2,120.00
50 
probes
Diamond DT-NCLR-50 $4,677.00
10 
probes
Conductive Diamond CDT-NCLR-10 $1,481.00
20 
probes
Conductive Diamond CDT-NCLR-20 $2,650.00
50 
probes
Conductive Diamond CDT-NCLR-50 $5,846.00


NANOSENSORS™ DT-NCLR AFM probes are designed for non-contact mode or tapping mode AFM (also known as: attractive or dynamic mode). The NCL type is offered as an alternative to NANOSENSORS™ high frequency non-contact probee (NCH). The NCL type cantilever is recommended if the feedback loop of the microscope does not accept high frequencies (400 kHz) or if the detection system needs a minimum cantilever length > 125 µm. Compared to the high frequency non-contact type NCH the maximum scanning speed is slightly reduced. This AFM probe combines high operation stability with outstanding sensitivity and fast scanning ability.

For applications that require hard contact between tip and sample this sensor offers a real diamond tip-side coating. This coating features extremely high wear resistance due to the unsurpassed hardness of diamond. The typical macroscopic tip radius of curvature is between 100 and 200 nm. Nanoroughnesses in the 10 nm regime improve the resolution on flat surfaces.

The probe offers unique features:

  • real diamond coating
  • tip height 10 - 15 µm
  • high mechanical Q-factor for high sensitivity
  • alignment grooves on backside of silicon holder chip
  • precise alignment of the cantilever position (within +/- 2 µm) when used with the Alignment Chip
  • compatible with PointProbe® Plus XY-Alignment Series

The DT Diamond coating is an approximately 100 nm thick coating of polycrystalline diamond on the tip-side of the cantilever leading to an unsurpassed hardness of the tip. The raman spectrum of the coating verifies the real diamond coating.

The reflex coating is an approximately 30 nm thick aluminum coating on the detector side of the cantilever which enhances the reflectivity of the laser beam by a factor of about 2.5. Furthermore it prevents light from interfering within the cantilever. The virtually stress-free coating is bending the cantilever less than 3.5% of the cantilever length.

Cantilever data:

Property Nominal Value Specified Range
Thickness /µm 7 6.0 - 8.0
Mean Width /µm 37.5 30 - 45
Length /µm 225 215 - 235
Force Constant /(N/m) 72 34 - 142
Resonance Frequency /kHz 210 155 - 275
More Information
Spring Constant (Nominal) 72 N/m
Spring Constant $72.00
Frequency (Nominal) 210 kHz
Frequency $210.00
Allow Set Quantities Yes