Nanosensors PPP-NCL

As low as $320.00
In stock
SKU
PPP-NCL -(select options)

Tapping Mode AFM Probe, Long Cantilever

Ordering Information

Quantity

Coating

Part Number

Price
10 
probes
None PPP-NCL-10 $320.00
20 
probes
None PPP-NCL-20 $573.00
50 
probes
None PPP-NCL-50 $1,265.00
10 
probes
Al (Reflex) PPP-NCLR-10 $320.00
20 
probes
Al (Reflex) PPP-NCLR-20 $573.00
50 
probes
Al (Reflex) PPP-NCLR-50 $1,265.00
10 
probes
PtIr5 (Overall) PPP-NCLPt-10 $449.00
20 
probes
PtIr5 (Overall) PPP-NCLPt-20 $803.00
50 
probes
PtIr5 (Overall) PPP-NCLPt-50 $1,771.00
10 
probes
Au (Reflex) PPP-NCLAuD-10 $320.00
10 
probes
Au (Overall) PPP-NCLAu-10 $384.00

The new PointProbe® Plus (PPP) combines the well-known features of the proven PointProbe® series such as high application versatility and compatibility with most commercial SPMs with a further reduced and more reproducible tip radius as well as a more defined tip shape. The typical tip radius of less than 7 nm and the minimized variation in tip shape provide more reproducible images and enhanced resolution.

NANOSENSORS™ PPP-NCL AFM probes are designed for non-contact mode or tapping mode AFM (also known as: attractive or dynamic mode). The NCL type is offered as an alternative to NANOSENSORS™ high frequency non contact type (NCH). PPP-NCL is recommended if the feedback loop of the microscope does not accept high frequencies (400 kHz) or if the detection system needs a minimum cantilever length > 125 µm. Compared to the high frequency non-contact type NCH the maximum scanning speed is slightly reduced. This probe type combines high operation stability with outstanding sensitivity and fast scanning ability.

The probe offers unique features:

  • guaranteed tip radius of curvature < 10 nm without coating.
  • tip height 10 - 15 µm
  • highly doped silicon to dissipate static charge
  • chemically inert
  • high mechanical Q-factor for high sensitivity
  • choice of various coatings.
  • alignment grooves on backside of silicon holder chip
  • precise alignment of the cantilever position (within +/- 2 µm) when used with the Alignment Chip
  • compatible with PointProbe® Plus XY-Alignment Series

Cantilever data:

Property Nominal Value Specified Range
Thickness /µm 7 6.0 - 8.0
Mean Width /µm 38 30 - 45
Length /µm 225 215 - 235
Force Constant /(N/m) 48 21 - 98
Resonance Frequency /kHz 190 146 - 236

More Information
Spring Constant (Nominal) 48 N/m
Spring Constant $48.00
Frequency (Nominal) 190 kHz
Frequency $190.00
Allow Set Quantities Yes
Featured Yes
Specs

Tapping Mode AFM Probe, Long Cantilever

© 2018 Nanoscience Instruments